FixVault

Tube, Water Inlet: Installation: Installation

Fig 1: Water Inlet Tube Mounting Bolts & Backside Of Water Pump
GC0148210Courtesy of CHRYSLER GROUP, LLC
  1. Install new O-ring seal onto the water tube elbow.
  2. Lubricate the O-ring seal with coolant to help aid in installation. Install elbow into the back side of the water pump.
  3. Install the mounting bolts (1). Tighten the water pump bolts (1) to 12 N.m (106 in. lbs.).
    Fig 2: Lower Oil Cooler Supply Hose & Water Inlet Tube
    GC0148207Courtesy of CHRYSLER GROUP, LLC
  4. Install the oil cooler hose (4).
    Fig 3: Hoses, EGR Cooler Supply Line, Temperature Sensor, Retaining Nuts & Thermostat Housing
    GC0145355Courtesy of CHRYSLER GROUP, LLC
  5. Install the thermostat housing (4). Refer to THERMOSTAT, INSTALLATION .
  6. Connect the negative battery cable.