Sensor, Oxygen: Removal: 6.2L: Downstream
- Disconnect and Isolate the negative battery cable
- Raise and support the vehicle. Refer to HOISTING, STANDARD PROCEDURE
.
- Disconnect the oxygen sensor wire harness connector (2).CAUTION:
When disconnecting the oxygen sensor electrical connector, do not pull directly on the wire going into the sensor. The sensor wiring can be damaged resulting in sensor failure.
- Remove the wire harness from the retainer.
- Remove the oxygen sensor (1).
- Clean the threads in the catalytic converters using an appropriate tap.