Sensor, Oxygen: Installation: 6.2L: Downstream

If reinstalling the original oxygen sensor, coat the sensor threads with an anti-seize compound such as Loctite 771- 64 or equivalent. New sensors have compound on the threads and do not require an additional coating. Do Not add any additional anti-seize compound to the threads of a new oxygen sensor. 

GC0170151Courtesy of CHRYSLER GROUP, LLC
  1. Install the oxygen sensor (1) and tighten to the proper specifications. Refer to TORQUE SPECIFICATIONS  .
    CAUTION:

    Never apply any type of grease to the oxygen sensor electrical connector, or attempt any repair of the sensor wiring harness.

  2. Connect the oxygen sensors wire harness connector (2) and secure the wire harness in the retainer.
  3. Remove support and lower the vehicle.