FixVault

Sensor, Manifold Absolute Pressure (Map): Installation: 2.4L

GC0155671Courtesy of CHRYSLER GROUP, LLC
  1. Inspect and replace the O-ring seal (1) if necessary.
    GC0169946Courtesy of CHRYSLER GROUP, LLC
  2. Install Manifold Absolute Pressure (MAP) sensor (1) and rotate 90° clockwise to lock in place.
  3. Connect the MAP sensor wire harness connector (2).
  4. Install the belly pan.
  5. Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector to the negative battery cable.