When Monitored
This diagnostic runs one time during an ignition cycle when the following conditions are met:
- During a cold start condition.
- When the difference between ambient temperature and engine coolant temperature is less than 10.0°C (18.0°F).
- The first 20 seconds of engine run time.
- The PCM checks the split injection for all four Fuel Injectors during a cold start. First pulse is 5% and second pulse is 95%.