FixVault

Cooling System Specifications

COOLING SYSTEM SPECIFICATIONS (SEPHIA & SPECTRA)

Application Specification
Coolant Replacement Interval (1) 30,000 Miles
Coolant Capacity 6.3 Qts. (6.0L)
Pressure Cap 15 psi (1.05 kg/cm2 )
Thermostat
Initial Opening 177-182°F (81-84°C)
Full Opening 203°F (95°C)
Full Opening Lift (2) .31" (7.9 mm)
(1) Or every 30 months, whichever comes first.
(2) Specification is minimum lift measurement. See Fig 1 .
COOLING SYSTEM SPECIFICATIONS (SPORTAGE)

Application Specification
Coolant Replacement Interval (1) 30,000 Miles
Coolant Capacity
W/ Heater 7.9 Qts. (7.5L)
W/O Heater 7.3 Qts. (6.9L)
Pressure Cap 15 psi (1.05 kg/cm2 )
Thermostat (2)
Initial Opening
Main 188-193°F (87-89°C)
Sub 182-188°F (83-87°C)
Full Opening 212°F (100°C)
Full Opening Lift (3)
Main .31" (7.9 mm)
Sub .06" (1.5 mm)
(1) Or every 30 months, whichever comes first.
(2) Cooling system is equipped with a 2-stage thermostat. Thermostat has a main and a sub valve within thermostat.
(3) Specification is minimum lift measurement. See Fig 1 .
Fig 1: Measuring Thermostat Full-Open Lift
G94D46360Courtesy of KIA MOTORS AMERICA, INC.