FixVault

Assembly Note: Locknut

  1. Shift to 1st gear.
  2. Lock primary shaft using SST(0K201 323 021 / K94A-4205-MT)  .
    Fig 1: Locking Primary Shaft
    G03057131
  3. Tighten new locknuts onto primary and secondary shafts.

    Tightening torque: 94 ~ 145 lb. ft. (128 ~ 196 N.m, 13 ~ 20 kg-m) 

  4. Stake locknuts.
  5. Measure the 5th gear thrust clearance using a dial indicator.

    Clearance: 0.004 ~ 0.009 in. (0.10 ~ 0.22 mm) 

    Maximum: 0.011 in. (0.27 mm) 

  6. If not as specified, disassemble and reassemble 5th and reverse gear assemblies.
    Fig 2: Measuring 5th Gear Thrust Clearance
    G03057132