FixVault

Transmission Range Sensor: Adjustments

  1. Place transaxle in Neutral. Ensure TR sensor electrical connector is disconnected and TR sensor retaining bolts are hand tight. Using DVOM, connect leads between TR sensor 9-pin connector terminals No. 6 and 9. See Fig 1 .
  2. Rotate TR sensor until continuity is present between terminals No. 6 and 9. Tighten 2 TR sensor retaining bolts to specification. See TORQUE SPECIFICATIONS  . Reconnect TR sensor electrical connector. Ensure vehicle starts only when gearshift lever is in "P" and "N" positions.
Fig 1: Identifying Transmission Range Sensor Connector Terminals
G99G54847Courtesy of FORD MOTOR CO.