Monitor Scantool Data
- IG KEY: ON, Engine: OFF
- Connect scantool to Data Link Connector (DLC) and select "CLOSED TP SWITCH" parameter on scantool.
- Is CLOSED TP SWITCH value near the specified value?
- Specification:
- Throttle valve fully closed: ON
- Throttle valve open a little: OFF
YES
- Fault is intermittent caused by poor contact in the sensor's and/or ECM's connector.
- Fault was repaired and ECM memory was not cleared.
- If the problem works out, Go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Go to "Inspection & Repair" procedure.
- Specification: