Water Temperature Sensor (WTS): Installation

  1. Apply sealant LOCTITE 962T or the equivalent to the threaded portion.
  2. Install the Water Temperature Sensor (WTS) and tighten it to the specified torque.

    Tightening Torque: 20~40 N.m (2~4 kg. m, 14~29 lb. ft)

  3. Securely connect the harness connector.