FixVault

Control Circuit Inspection

  1. Key "OFF".
  2. Disconnect ISCA connector and Key "ON".
  3. Measure the voltage between terminal 1 of ISCA harness connector and chassis ground.
  4. Measure the voltage between terminal 3 of ISCA harness connector and chassis ground.

    Specification: Approx 1.3V (at terminal 1), Approx 2V (at terminal 3)

  5. Is the measured voltage within specification?

    YES 

    NO