Warning Lamp Behavior After Ignition On
As soon as the operating voltage is applied to the SRSCM ignition input, the SRSCM activates the warning lamp for a bulb check.
The lamp shall turn on for 6 seconds during the initialization phase and be turned off afterward. However, in order to warn the driver, the warning lamp shall turn on for 6 seconds and off for one second then on continuously after the operating voltage is applied if any active fault exists.
- Active fault or historical fault counter is greater or equal to 10
- Normal or historical fault counter is less than 10