Heated Oxygen Sensor (Ho2S)
›
Inspection
›
Specification
›
Ho2S [Bank 1/Sensor 2]
Ho2S [Bank 1/Sensor 2]
SENSOR OUTPUT VOLTAGE SPECIFICATION
A/F Ratio
Output Voltage (V)
RICH
0.6 ~ 1.0
LEAN
0.1 ~ 0.4
HEATER RESISTANCE SPECIFICATION
Item
Specification
Heater Resistance (Ω)
Approx. 9.0Ω at 20 °C (68°F)