DTC P0030 Ho2S Heater Control Circuit (Bank 1/Sensor 1)
›
Specification
DTC P0030 Ho2S Heater Control Circuit (Bank 1/Sensor 1): Specification
RESISTANCE SPECIFICATION
ITEM
Specification
Heater Resistance (Ω)
Approx. 9.0Ω at 20°C (68°F)