FixVault

Ground Circuit Inspection

  1. IG "OFF".
  2. Disconnect Fuel Level Sensor connector.
  3. IG "ON".
  4. Measure the voltage between terminal 4 of Fuel Level Sensor harness connector and ground (A).

    Measure the voltage between terminal 1 and 4 of Fuel Level Sensor harness connector (B).

    Specification: "A" - "B" = Below 200mV

    Fig 1: Measuring Voltage Between Terminal 1 And 4 Of Fuel Level Sensor Harness Connector
    G06130670Courtesy of KIA MOTORS AMERICA, INC.
  5. Is the measured voltage within specification?

    YES 

    NO