HO2S [Bank 1/Sensor 2]

AIR/FUEL RATIO AND OUTPUT VOLTAGE - HEATED OXYGEN SENSOR

A/F Ratio Output Voltage (V)
RICH 0.6 ~ 1.0
LEAN 0.1 ~ 0.4
HEATER RESISTANCE (BANK 1 / SENSOR 2) - HEATED OXYGEN SENSOR

Item Specification
Heater Resistance (Ω) 3.3 ~ 4.1 [20°C (68°F)]