FixVault

Manifold Absolute Pressure Sensor (MAPS): Specifications: Specification

OUTPUT VOLTAGE SPECIFICATIONS

Pressure (kPa) Output Voltage (V)
20.0 0.79
46.66 1.84
101.32 4.0
Fig 1: Output Voltage/Pressure Graph
G06486580Courtesy of KIA MOTORS AMERICA, INC.