FixVault

P0154: O2 Sensor Circuit No Activity Detected (Bank 2/Sensor 1): DTC Detecting Condition

DTC DETECTING CONDITION CHART

Item Detecting Condition Possible cause
DTC Strategy
  • Monitor signal voltage
  • Poor connection
  • Open in harness
  • HO2S(B2/S1)
  • ECM
Enable Conditions
  • Battery voltage ≥ 10V
  • Engine running ≥ 60 sec.
  • Engine warm-up state
  • No disable faults
Threshold value Case 1
  • 1.2V ≤Voltage of HO2S ≤ 3.9V(at pumping current ON)
Case 2
  • 0.415V ≤ Voltage of HO2S ≤ 0.515V(at pumping current OFF)
Diagnosis Time
  • Continuous (more than 76.5 sec.failure for every 90 sec. test)
MIL On Condition
  • 2 driving cycles