Repair Procedures: Specification
TEMPERATURE AND RESISTANCE SPECIFICATION CHART
| Ambient temperature (°C (°F)) | Resistance between terminals 1 and 2 (kΩ) |
|---|---|
| -10 (14) | 164.2 |
| 0 (32) | 97.5 |
| 10 (50) | 59.6 |
| 20 (68) | 37.46 |
| 30 (86) | 24.18 |
| 40 (104) | 16 |
- 4. If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
- 5. If the problem is corrected, replace the ambient temperature sensor.