FixVault

Initializing Method Of The Safety Power Window

  1. Initializing of Battery Connection
    1. Power window operation before initializing
      1. Manual-Up/Down function is available
      2. Auto-Up function is not available

      (When holding the auto-up/down switch, window is operated as a manual-up/down.)

    2. Initializing method

    Close the window in window open position, and holding the switch in window full close position more than 1 second.