FixVault

Repair Procedures: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. Ignition "OFF"
  2. Disconnect the connector of mode control actuator.
  3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3 and grounding terminal 7.
  4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.
    Fig 1: Identifying Mode Control Actuator Connector Terminals
    G08309724Courtesy of KIA MOTORS AMERICA, INC.
  5. Check the voltage between terminals 5 and 6.
    VOLTAGE SPECIFICATION

    Door position Voltage(4-5) Error detecting
    Max. cooling 0.3 ± 0.15V Low voltage: 0.1V or less
    Max. heating 4.7 ± 0.15V High voltage: 4.9V or more

    It will feedback current position of actuator to controls.

  6. If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation.
  7. If the problem is corrected, replace the mode control actuator.