Error detection
- Error detection for seats
The PSM detects an error when one of the following conditions occurs during a recall operation, getting in or out operation, or manual switch-based operation.
- Error conditions
- Slide: Fewer than 6 pulses within 2 seconds
- Backrest: Fewer than 8 pulses within 2 seconds
- Front height adjustment: Fewer than 6 pulses within 1 seconds
- Rear height adjustment: Fewer than 6 pulses within 1.5 seconds
- Cushion extension: Fewer than 6 pulses within 1 second
- Headrest: Fewer than 6 pulses within 1 second
- Error recovery conditions
- Slide: 6 pulses or more within 2 seconds
- Backrest: 8 pulses or more within 2 seconds
- Front height adjustment: 6 pulses or more within 1 seconds
- Rear height adjustment: 6 pulses or more within 1.5 seconds
- Cushion extension: 6 pulses or more within 1 second
- Headrest: 6 pulses or more within 1 second