FixVault

Component Inspection

■ Check HO2S (B1/S1) Heater resistance 

  1. IG "OFF". Disconnect HO2S (B1/S1) connector.
  2. Measure resistance between power and control terminals of HO2S (B1/S1) heater (Component Side)

    Specification:  3.3 ~ 4.1[20°C (68°F)]

  3. Is the measured resistance within specification?

    YES 

    NO 

    • Substitute with a known - good HO2S and check for proper operation. If the problem is corrected, go to "VERIFICATION OF VEHICLE REPAIR " procedure.