FixVault

Repair Procedures: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. Connect the GDS on the Data Link Connector (DLC).
  2. Turn the ignition switch ON.
  3. Measure the output voltage of the APS 1 and 2 at C. T and W.O. T.

    Specification:  Refer to "Specification "