FixVault

Signal Circuit Inspection

■ Check Open Or Short In Signal Circuit 

  1. IG KEY "OFF".
  2. Disconnect HO2S (S1) _UP connector.
  3. IG KEY "ON" & ENG "OFF"
  4. Measure the voltage between Virtual Ground terminal "3" of HO2S (S1) _UP harness connector and chassis ground.

    Measure the voltage between Nearest Voltage terminal "1" of HO2S (S1) _UP harness connector and chassis ground.

    Measure the voltage between Current Pump terminal "1" of HO2S (S1) _UP harness connector and chassis ground.

    Measure the voltage between Trim Resistor terminal "4" of HO2S (S1) _UP harness connector and chassis ground.

    Specification: 

    Virtual Ground: Approx 2.5V

    Nearest Voltage: Approx 2.9V

    Current Pump: Approx 2.8V

    Trim Resistor: Approx 2.8V

  5. Is the measured voltage within specification?

    YES 

    NO