FixVault

Repair Procedures: Inspection

  1. Disconnect the battery negative terminal.
  2. Remove the fuse box cover.
  3. Remove the starter relay (A).
    G11954802Courtesy of
  4. Using an ohmmeter, check that there is continuity between each terminal.
    Terminal Value Measure
    30 - 87 1 MΩ or Higher If there is continuity, replace the relay.
    G11954803Courtesy of
  5. Apply 12V to terminal 85 and ground to terminal 86.

    Check for continuity between terminals 30 and 87.

    Terminal Value Measure
    30 - 87 1 Ω or less If there is no continuity between the terminals, replace the relay.
    G11954804Courtesy of
  6. If there is no continuity, replace the starter relay.
  7. Install the starter relay.
  8. Install the fuse box cover.