FixVault

Repair Procedures: Removal

  1. Disconnect the battery terminals (A).
    1. Tightening torque 

      (+) terminal:

      7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)

      (-) terminal:

      4.0 ~ 6.0 N.m (0.4 ~ 0.6 kgf.m, 3.0 ~ 4.4 lb-ft)

      G11955607Courtesy of
  2. Remove the air duct and air cleaner assembly. (Refer to "AIR CLEANER .")
  3. Remove the battery insulation pad.
  4. Remove the battery (A) after removing the mounting bracket.

    Tightening torque: 

    8.8 ~ 13.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft)

    G11955608Courtesy of
  5. Remove the ECM.

    (Refer to "ENGINE CONTROL MODULE (ECM) .")

  6. Remove the battery tray (A) after removing the bolts.

    Tightening torque: 

    8.8 ~ 13.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft)

    G11955609Courtesy of