FixVault

Repair Procedures: Replacement

  1. Remove the air cleaner assembly.

    (Refer to "AIR CLEANER .")

  2. Remove the battery and battery tray.

    (Refer to "BATTERY .")

  3. Disconnect the back up lamp switch connector (A).
    G11950357Courtesy of
  4. Remove the back up lamp switch (A).
    G11950358Courtesy of
  5. Replace a new one and install the back up lamp switch.

    Tightening torque: 

    39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)