Control Circuit Inspection

Check open in harness 

  1. IG "OFF" & Disconnect HO2S (S1)_UP connector.
  2. IG "ON".
  3. Measure the voltage between heater control terminal "5" of HO2S (S1)_UP harness connector and chassis ground.

    Specification  : Approx. 3.5V

  4. Is the measured voltage within specification?

    YES 

    NO