FixVault

Control Circuit Inspection

Check Short in control circuit 

  1. IG "OFF" & Disconnect HO2S (S2)_DOWN connector.
  2. IG "ON".
  3. Measure the voltage between heater control terminal "4" of HO2S (S2)_DOWN harness connector and chassis ground.

    Specification  : Approx. 3.5V

  4. Is the measured voltage within specification?

    YES 

    NO