FixVault

Repair Procedures: Replacement

  1. Disconnect the negative (-) battery terminal.
  2. Remove the glove box housing.

    (Refer to Body - "GLOVE BOX HOUSING ")

  3. Disconnect the cluster ionizer connector (A).
  4. Remove the screws and then remove the cluster ionizer (B).
    Fig 1: Disconnecting Cluster Ionizer Connector
    G12166730Courtesy of KIA MOTORS AMERICA, INC.
  5. Install in the reverse order of removal.