FixVault

Repair Procedures: Inspection

  1. Turn the ignition switch OFF.
  2. Disconnect the OCV connector.
  3. Measure resistance between the OCV terminals 1 and 2.
  4. Check that the resistance is within the specification.
    Item Specification
    Coil Resistance (Ω) 6.9 - 7.9 [20°C (68°F)]