Repair Procedures: Removal

  1. Remove the air cleaner assembly and air duct.

    (Refer to Engine Machanical System - "AIR CLEANER ")

  2. Loosen the reservoir mounting bolts (A).

    Tightening torque  :

    3.9 - 5.9 N.m (0.4 - 0.6 kgf.m, 2.9 - 4.3 lb.ft)

    Fig 1: Loosening Reservoir Mounting Bolts
    G12309139Courtesy of KIA MOTORS AMERICA, INC.
  3. Disconnect the TCM connector (A).
    Fig 2: Disconnecting TCM Connector
    G12309140Courtesy of KIA MOTORS AMERICA, INC.
  4. Remove the TCM loosening the bolt (B) and nuts (A).

    Tightening torque  :

    9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb.ft

Fig 3: Removing TCM Bolt And Nuts
G12309141Courtesy of KIA MOTORS AMERICA, INC.