FixVault

Control Circuit Inspection

Check Open in Harness 

  1. IG "OFF" & Disconnect HO2S (S1) connector.
  2. IG "ON".
  3. Measure voltage between control terminal of HO2S (S1) heater harness connector and chassis ground.

    Specification:  Approx. 3.5V

    Fig 1: Measuring Voltage Between Control Terminal Of HO2S (S1) Heater And Chassis Ground
    G11847278Courtesy of KIA MOTORS AMERICA, INC.
    Fig 2: Heater Control Connector Terminal
    G11847279Courtesy of KIA MOTORS AMERICA, INC.
  4. Is the measured voltage within specification?

    YES 

    NO