FixVault

Repair Procedures: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. Turn the ignition switch OFF.
  2. Disconnect the RCV control solenoid valve connector.
  3. Measure resistance between the valve terminals 1 and 2.
    Fig 1: Locating RCV Control Solenoid Valve Connector Terminals
    G12170504Courtesy of KIA MOTORS AMERICA, INC.
  4. Check that the resistance is within the specification.

    Specification:  28.3 ~ 31.1 Ω [20°C (68°F)]