CVVT Oil Control Valve (OCV)
›
Repair Procedures
›
Inspection
Repair Procedures: Inspection
Turn the ignition switch OFF.
Disconnect the OCV connector.
Measure resistance between the OCV terminals 1 and 2.
Check that the resistance is within the specification.
CVVT OIL CONTROL VALVE (OCV) SPECIFICATION
Item
Specification
Coil Resistance (Ω)
6.9 - 7.9 [20°C (68°F)]