DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Rationality check
  • Poor connector connection
  • Short/open in upstream O2 sensor signal circuit
  • Faulty upstream O2 sensor
General Enable Conditions
  • Dew point end detected
  • Fuel feed back control active
  • Battery voltage is greater than 11V
  • Exhaust Gas temperature is 280°C to 800°C
  • No injector error
  • No upstream O2 sensor heater error
Case 1 Enable Conditions
  • S2 sensor voltage is greater than 0.5V
Threshold Value
  • S1 sensor voltage is 0.06V to 0.4V
Diagnostic Time
  • 25s
Case 2 Enable Conditions
  • S2 sensor voltage is less than 0.1V
Threshold Value
  • S1 sensor voltage is 0.06V to 0.4V
Diagnostic Time
  • 10s
Case 3 Enable Conditions
  • Continuous
Threshold Value
  • The number of that the absolute value of Δusvk is greater than 2V during 0.04s after turning on and off a heater is more than or equal to 5 times
Diagnostic Time
  • -
MIL ON Condition
  • 3 driving cycles