FixVault

[Bank 2/Intake]

  1. Turn the ignition switch OFF and disconnect the battery negative (-) terminal.
  2. Remove the intake manifold.

    (Refer to Engine Mechanical System - "INTAKE MANIFOLD ")

  3. Disconnect the CVVT oil control valve connector (A).
  4. Remove the installation bolt (B), and then remove the valve from the engine.
Fig 1: Disconnecting CVVT Oil Control Valve Connector (Bank 2/Intake)
G12181563Courtesy of KIA MOTORS AMERICA, INC.