FixVault

Repair Procedures: Inspection

  1. Switch "OFF" the ignition.
  2. Disconnect the IATS connector.
  3. Measure resistance between the IATS terminals 3 and 4.
  4. Check that the resistance is within the specification.
Temperature Resistance (kΩ)
°C °F
-40 -40 38.88 - 50.77
-20 -4 13.19-16.82
0 32 5.11 -6.11
10 50 3.30 - 4.09
20 68 2.19-2.69
40 104 1.02-1.26
60 140 0.51 -0.64
80 176 0.27 - 0.35