FixVault

DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Electrical monitoring
  1. Poor Connector Connection
  2. Signal circuit power short
  3. Ground circuit open
  4. Rail pressure sensor
  5. ECM
Enable Conditions
  • Ignition "ON"
Threshold Value
  • Voltage average of rail pressure higher than 4.8V
  • Signal circuit of sensor is short to power or open
Diagnostic Time
  • Continuous inspection
MIL ON Condition
  • 2 driving cycles