FixVault

Starter Solenoid Inspection

  1. Disconnect the lead wire from the M-terminal of solenoid switch.
  2. Connect the battery as shown. If the starter pinion pops out, it is working properly.
    NOTE:
    • To avoid damaging the starter, do not leave the battery connected for more than 10 seconds.
    G13143471Courtesy of KIA MOTORS AMERICA, INC.
  3. Disconnect the battery from the M terminal.

    If the pinion does not retract, the hold-in coil is working properly.

    NOTE:
    • To avoid damaging the starter, do not leave the battery connected for more than 10 seconds.
    G13143472Courtesy of KIA MOTORS AMERICA, INC.
  4. Disconnect the battery also from the body. If the pinion retracts immediately, it is working properly.
NOTE:
  • To avoid damaging the starter, do not leave the battery connected for more than 10 seconds.
G13143473Courtesy of KIA MOTORS AMERICA, INC.