FixVault

Repair Procedures: Inspection

  1. Measure a resistance of NTC and Heated pad.
    • NTC resistance (Black/Red - Black): 10.0 kΩ ± 10 % [at 25°C (77°F)]
    • Heated pad resistance (Black - Yellow): 1.85Ω ± 0.2Ω
  2. Measure a temperature.
    • The temperature of wheel surface grip must rise from -20°C (-4°F) to 20°C (68°F) within 6 minute
    • The temperature of wheel surface grip must keep 38 ± 4°C (100.4 ± 39.2°F) after 25 minute
    • At that time switch on, all measure point (1 - 8)
    G13211351Courtesy of KIA MOTORS AMERICA, INC.