[Feedback Position Sensor]

  1. Connect the KDS to the data link connector.
  2. Fully open and fully close the EEGR valve by conducting the actuation test.
  3. Check that the voltage is within the specification
Item Specification
Sensor Power (V) 5
Pin 3
Closed Voltage (V) 3.85 - 4.15
Open Voltage (V) 0.75 - 1.25