Repair Procedures: Inspection: Notes
WARNING: This page is about a different variant/trim than selected.
Inspect the PTC operation with the confirmation logic below:
- Entering
- Set the mode to FLOOR.
- Set the temperature to MAX HOT.
- Turn off the blower switch.
- Press the intake (recirculation) button 5 times or more.
- Forced operation
- Non-A/C: The intake button indicator will blink with an interval of 0.5 second for 30 seconds.
With A/C: The intake and A/C button indicator will blink with an interval of 0.5 second for 30 seconds.
- The PTC2 and PTC3 will operate by turning on the blower switch.
- PTC2 and PTC3 will operate with an interval of 3 seconds.
- PTC2 and PTC3 will turn off simultaneously when the blower switch is turned off.
- Only PTC2 and PTC3 will be operated by force.
- Non-A/C: The intake button indicator will blink with an interval of 0.5 second for 30 seconds.
- Cancellation
- Select A/C or intake (recirculation) switch.
- The test cancels automatically after 30 seconds.
- Turn the ignition switch off.