Repair Procedures: Replacement

WARNING: This page is about a different variant/trim than selected.
  1. Discharge refrigerant from refrigeration system.
  2. Replace faulty tube or hose.
    CAUTION: Cap the open fittings immediately to keep moisture or dirt out of the system.
  3. Tighten joint of bolt or nut to specified torque.
    CAUTION: Connections should not be torque tighter than the specified torque.
    TIGHTENING TORQUES SPECIFICATIONS

    Part tightened N.m kgf.m lb.ft
    Condenser - Discharge hose 7.8-11.8 0.8-1.2 5.8-8.7
    Condenser - Liquid tube
    Compressor - Discharge hose 7.8-11.8 0.8-1.2 5.8-8.7
    Compressor - Suction hose
    Expansion valve - Evaporator 7.8-11.8 0.8-1.2 5.8-8.7
  4. Evacuate air in refrigeration system and charge system with refrigerant.

    Specified amount:  570 ± 25g (20.1 ± 0.88oz.)

  5. Inspect for leakage of refrigerant.

    Using a gas leak detector, check for leakage of refrigerant.

  6. Inspect A/C operation.