FixVault
Home
›
Kia
›
2021
›
Forte EX
›
Repair and Diagnosis
›
Heating, Ventilation & A/C (HVAC)
›
HVAC Control Systems
›
Air Conditioning System
›
Evaporator Temperature Sensor
›
Repair Procedures
›
Specification
Repair Procedures: Specification
Evaporator core temperature [°C (°F)]
Resistance [KΩ]
Voltage [V]
-10 (14)
43.35
2.96
0 (32)
27.62
2.4
10 (50)
18.07
1.88
20 (68)
12.11
1.44
30 (86)
8.30
1.08
40 (104)
5.81
0.81
Courtesy of KIA MOTORS AMERICA, INC.