Repair Procedures: Installation
- To install, reverse the removal procedure.CAUTION: Plug or cap the lines immediately after disconnecting them to avoid moisture and dust contamination.
- Tighten the bolt or nut joint to the specified torque.
- Using a gas leak detector, check for refrigerant leakage.
- Evacuate air in the refrigeration system and charge system with refrigerant.
Capacity: 500 ± 25 g (17.6 ± 0.88 oz.)