FixVault

Repair Procedures: Installation

  1. To install, reverse the removal procedure.
    CAUTION: Plug or cap the lines immediately after disconnecting them to avoid moisture and dust contamination.
    • Tighten the bolt or nut joint to the specified torque.
    • Using a gas leak detector, check for refrigerant leakage.
    • Evacuate air in the refrigeration system and charge system with refrigerant.

    Capacity:  500 ± 25 g (17.6 ± 0.88 oz.)