FixVault

Component Inspection: Notes

Inspect ECTS
Inspection Condition (+) Probe (-) Probe Reference
Connector Terminal Connector Terminal
  1. Ignition "OFF".
  2. Disconnect the electrical connector(s) from the concerned component.
ECTS (component side) 3 (signal) ECTS (component side) 1 (ground) Table1