FixVault

Repair Procedures: Installation

  1. Install in the reverse order of removal.
  2. Perform air-tight inspection.

    (Refer to Vehicle Control System - "AIR TIGHTNESS ")

  3. Fill the coolant and then check for leakage.
    NOTE:
    • Refill the motor cooling system with coolant and then bleed the air using the KDS.

      (Refer to Motor Cooling System - "COOLANT ")

  4. Install the motor assembly then perform "INITIALIZATION OF MOTOR/HSG RESOLVER CALIBRATION " procedure.
    NOTE:
    • If "Initialization of Automatic Resolver Offset Calibration" is not reset after exchanging the motor, it may result in reduced max power output as well as drive range.

      (Refer to Motor & Reduction Gear - "MOTOR POSITION AND TEMPERATURE SENSOR ")