Component Inspection: Notes
Inspection Procedure
Visual inspection
- Immerse thermostat in water heated to over 95°C (203°F), then heat for at least 3 minutes to check valve lift.NOTE: Do not immerse connector part.
- Check the valve opening temperature.
Valve opening temperature:
100 ± 2°C (212±3.6°F)
Full opening temperature: 113°C (235°F)
If the valve opening temperature is not as specified, replace the thermostat.
- Check the valve lift.
Valve lift: 8 mm (0.3150 in.) or more at 113°C (235°F)
If the valve lift is not as specified, replace the thermostat.
- Specification:
8 mm (0.3150 in.) or more at 113°C (235°F)
Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found, replace the Thermostat and go to "VERIFICATION OF REPAIR " procedure.
No Good
- Repair or replace as necessary and then, go to "VERIFICATION OF REPAIR " procedure.